WIND TURBINE FOUNDATIONS
Avalon has installed high capacity helical piers and anchors for wind turbines and other towers, including this 320 foot tall wind turbine at the Budweiser plant in Fairfield, California.

Engineering by:
Allan Henderson,
Patrick and Henderson, Inc.

Inspections by:
Charles Lloyd Purdy,
Structural Observation Services

Pier Manufacturer:
Viking Helical Anchors
Avalon Structural installed the helical piles for this 350 foot tall turbine in Soledad, CA. The soil under the tower, and around the helical plates, was pressure grouted via ports in the helical pile shafts for additional capacity.

Engineering by:
Allan Henderson,
Patrick and Henderson, Inc.

Inspections by:
Charles Lloyd Purdy,
Structural Observation Services

Pier Manufacturer:
Magnum Piering

Soils Engineering:
Judd King, PE, GE
Earth Systems Pacific
The following animation illustrates the process.
A wind turbine foundation ready for helix installation. Using helix piers for compression and tension loads, the excavation, and therefore concrete usage, is minimal.

Engineering by:
Allan Henderson,
Patrick and Henderson, Inc.

Inspections by:
Charles Lloyd Purdy,
Structural Observation Services

Pier Manufacturer:
Viking Helical Anchors
Avalon installing the second helical deep foundation for a wind tower for Budweiser in Fairfield, CA. Each pier has a compression and tension capacity of over 250,000 lbs before grouting.

Engineering by:
Allan Henderson,
Patrick and Henderson, Inc.

Inspections by:
Charles Lloyd Purdy, of
Structural Observation Services

Pier Manufacturer:
Magnum Piering
Avalon performing a tension test with Charles Lloyd Purdy, PE, of Structural Observation Services.
Helical piers for a wind turbine for the County of Monterey in Soledad, CA.
As the helical pile is installed, it is constantly checked for plumbness.
A tension test in Dixon, CA. The pier passed a 147,000 lb pull test without grout.
Both compression and tension capacity of helix can be increased inexpensively by pressure grouting. For this wind turbine foundation, Avalon pressure grouted the soil around the helical discs. Grout was pumped through the helix pier shaft under 900 psi to densify and strengthen the soil.

Engineering by:
Allan Henderson,
Patrick and Henderson, Inc.

Inspections by:
Charles Lloyd Purdy
Structural Observation Services
Avalon Structural, Inc.
181 Ridgeview Drive
Aptos, CA 95003
(831) 479-4389 (office)
info@avalonstructural.com
Copyright © 2015
Avalon Structural, Inc.
All Rights Reserved
CA License 677116
Classifications:  B, C-8
Avalon is a general building
contracting firm and
does not employ engineers.